Everyone is so modest! lets get down to business!!
/usr/platform/sun4u/sbin/prtdiag
System Configuration: Sun Microsystems sun4u Sun Fire 6800
System clock frequency: 150 MHz
Memory size: 8192 Megabytes
========================= CPUs =======================================
+========
Port Run E$ CPU CPU
FRU Name ID MHz MB Impl. Mask
---------- ---- ---- ---- ------- ----
/N0/SB0/P0 0 1050 8.0 US-III+ 2.3
/N0/SB0/P1 1 1050 8.0 US-III+ 2.3
/N0/SB0/P2 2 1050 8.0 US-III+ 2.3
/N0/SB0/P3 3 1050 8.0 US-III+ 2.3
========================= Memory Configuration =======================
+========
Logical Logical Logical
Port Bank Bank Bank DIMM Interleave
+ Interleave
FRU Name ID Num Size Status Size Factor
+ Segment
------------- ---- ---- ------ ----------- ------ ----------
+ ----------
/N0/SB0/P0/B0 0 0 1024MB pass 512MB 8-way
+ 0
/N0/SB0/P0/B0 0 2 1024MB pass 512MB 8-way
+ 0
/N0/SB0/P1/B0 1 0 1024MB pass 512MB 8-way
+ 0
/N0/SB0/P1/B0 1 2 1024MB pass 512MB 8-way
+ 0
/N0/SB0/P2/B0 2 0 1024MB pass 512MB 8-way
+ 0
/N0/SB0/P2/B0 2 2 1024MB pass 512MB 8-way
+ 0
/N0/SB0/P3/B0 3 0 1024MB pass 512MB 8-way
+ 0
/N0/SB0/P3/B0 3 2 1024MB pass 512MB 8-way
+ 0
========================= IO Cards =========================
Bus Max
+
IO Port Bus Freq Bus Dev,
+
FRU Name Type ID Side Slot MHz Freq Func State Name
+ Model
---------- ---- ---- ---- ---- ---- ---- ---- ----- -----------------
+--------------- ----------------------
/N0/IB9/P0 PCI 30 B 0 33 33 1,0 ok pci-pci1011,25.4/
+pci108e,1000 pci-bridge
/N0/IB9/P0 PCI 30 B 0 33 33 0,0 ok pci108e,1000-pci1
+08e,1000.1
/N0/IB9/P0 PCI 30 B 0 33 33 0,1 ok SUNW,qfe-pci108e,
+1001 SUNW,pci-qfe
/N0/IB9/P0 PCI 30 B 0 33 33 1,0 ok pci108e,1000-pci1
+08e,1000.1
/N0/IB9/P0 PCI 30 B 0 33 33 1,1 ok SUNW,qfe-pci108e,
+1001 SUNW,pci-qfe
/N0/IB9/P0 PCI 30 B 0 33 33 2,0 ok pci108e,1000-pci1
+08e,1000.1
/N0/IB9/P0 PCI 30 B 0 33 33 2,1 ok SUNW,qfe-pci108e,
+1001 SUNW,pci-qfe
/N0/IB9/P0 PCI 30 B 0 33 33 3,0 ok pci108e,1000-pci1
+08e,1000.1
/N0/IB9/P0 PCI 30 B 0 33 33 3,1 ok SUNW,qfe-pci108e,
+1001 SUNW,pci-qfe
/N0/IB9/P1 PCI 31 B 5 33 33 2,0 ok scsi-glm/disk (bl
+ock) Symbios,53C875
/N0/IB9/P1 PCI 31 B 5 33 33 2,1 ok scsi-glm/disk (bl
+ock) Symbios,53C875
========================= Active Boards for Domain ===================
+========
Power Fault HotPlug Board
FRU Name LED LED LED Cond.
-------- ----- ----- ------- -------
/N0/SB0 on off off ok
/N0/IB9 on off off ok
========================= Available Boards/Slots for Domain ==========
+========
Power Fault HotPlug Board/Slot Board/Slot
FRU Name LED LED LED Condition Assigned
-------- ----- ----- ------- ---------- ----------
/SB1 on off off ok no
========================= Hardware Failures ==========================
+========
No Hardware failures found in System